Campbell Hausfeld air compressor is an oiled unit that is designed for them who undertake menial tasks at home. Even for small calibration automotive technicians as this compressor can power impact wrenches, spray guns, and other air tools.

The ambient air contains traces of moisture when the same air get'south compressed, the moisture gets condensed. And then don't forget to install an air dryer or a water filter, especially when your job requires completely dry air.

There'southward a transmission/user guide attached to the unit y'all buy, which is very, very of import. You need to empathize all the condom guidelines, precautionary measures first, to run the compressor safely and efficiently.

At present permit'south run into in detail how to unpack, get together, install and operate the Campbell Hausfeld air compressor.

Contents

  • one How to Use the Campbell Hausfeld Air Compressor?
    • 1.ane Unpacking:
    • one.two Assembling:
    • i.3 Installation:
      • 1.3.1 Air Filter.
      • 1.3.two Electrical wiring.
    • ane.4 Functioning:
      • 1.4.i Main switch.
      • 1.4.two ASME safety valve.
      • 1.4.3 Regulator.
      • 1.4.4 Cheque valve.
      • 1.4.5 Exhaust tube.
      • i.4.6 Drain valve.
      • 1.4.7 Handle.
      • 1.four.eight Operating steps involved:
  • two How to connect and disconnect the portable compressor?
    • ii.one Disconnecting:
    • ii.2 Connecting:
  • 3 Pressure gauges
  • four Maintenance
  • 5 Conclusion.

How to Use the Campbell Hausfeld Air Compressor?

Unpacking:

I am sure there's no need to tell you how to unpack.
So when y'all are done with the unpacking, bank check the unit for whatever damage which might have caused due to transportation.

Subsequently that cheque the bolts and other fittings, if they are loose then tighten them before you start the unit.

Assembling:

Part of assembling is the lubrication.
When it comes to lubrication, Ever utilize the oil which is packed with the compressor.

Note: In case there'due south no oil with the shipment, and so look in the manual for instructions regarding lubrication.

Besides remember not to utilize whatever common auto oil (e.chiliad. 10W-30), as these oils consist of additives they get accumulated on the valves thus affecting the life span of the pump.

If y'all want the pump to terminal long, which I am sure you do, so replace the oil afterward running the compressor for the outset few hours. Just accept to do information technology in one case.

Effectually 13 ozs (380 ml) is the corporeality of oil needed by your compressor, the level of oil is visible through the sight glass present on the crankcase area of the pump.

Note: Don't overfill the tank, the oil level should attain "max" present on the sight glass.

Installation:

Air Filter.

Installing an air filter is of utmost importance, information technology is threaded onto the side of the compressor.

While installing this make sure that your surrounding is clean, tidy and completely ventilated.

At least 20 inches of distance should be present between the compressor and the wall, this volition prevent whatever objects from acting equally an obstruction.

Electrical wiring.

  • Depending upon your locality the electric wiring code varies, brand sure yous know your local code.
  • Plug, wiring, and protector should be suitable for the compressor's voltage and amperage.
  • The power cord of the compressor has a grounding facility, keep in mind that the electrical outlet is grounded as well, as this helps during brusque circuits.

YouTube video

Operation:

Main switch.

Off or Auto switch, when you plough the switch tooff the compressor will shut down, this is what you should do when yous have to either connect or disconnect the power string.

When you lot turn the lever to auto the compressor will start compressing the air, and when the tank reaches its max level information technology automatically shuts downwards the unit.

ASME safety valve.

In case the tank force per unit area exceeds the maximum preset level, this valve volition release the actress air immediately.

Regulator.

This knob controls the air force per unit area at the release outlet.

Check valve.

It'due south a one-way valve that prevents the backflow of air into the pump.

Exhaust tube.

The job of this tube is to comport the air from the pump to the check valve, as it happens it gets very hot while the compressor is working, and so avoid touching the tube.

Drain valve.

Present at the underside of the tank, use this valve to bleed moisture from the tank. Do information technology regularly to avert corrosion.

Note: Make sure the tank pressure is not above x psi.

Handle.

It is designed to aid yous to move your compressor.

Operating steps involved:

  1. Plough the regulator knob to the left to stop the airflow.
  2. Attach the air hose with the outlet of the regulator.
  3. Turn the switch to offposition.
  4. Plug the ability cord in.
  5.  At present turn the switch to theautoposition, the compressor will run until the pressure reaches the maximum, then it gets automatically turned off.
  6. Attach whatever air tool at the cease of the hose.
  7. Lastly, turn the regulator knob to the correct side and set the desired force per unit area for the air tool that you lot are about to use.

How to connect and disconnect the portable compressor?

Disconnecting:

  • By holding the neckband present on the coupler remove the connecting hose.
  • Now remove the knob past unscrewing information technology.
  • Push the larger tank back and then that y'all tin pull the small one forward, at present unhook the base of operations of those two tanks.
  • For storage purposes, replace that knob in the larger tank.

Connecting:

  • Y'all need to make sure that the feet of both the tanks are aligned. And so that the foot subclass of pocket-size one fits into the foot bracket opening of the large ane.
  • Just equally before, push the bank and bring the large tank forward to mount the holding pins of the large ones into the holes of a minor i.
  • Connect the knob, it volition secure the large tank with the small tank's handle.
  • Reattach the connecting hose.

Pressure gauges

There are 2 gauges present, one on the left side of the regulator which shows the pressure level going towards hose including whatever air tool fastened to it.

Some other is present on the correct side of the regulator, which shows the air pressure of the tank.

Maintenance

  • Pull the ASME safety valve to release the pressure from the unit of measurement, after turning the compressor off.
  • Using the bleed valve removes the wet from the tank, tilt the tank if needed.
  • Make clean-up dust particles from the intake air filter, valve, pump, and air lines.
  • Supplant oil later on fifty hours of usage, bleed the oil by removing the oil bleed plug.

Conclusion.

Follow these steps carefully and call back to continue the unit of measurement away from any spraying surface area.

When your compressor is not in utilise make sure information technology is in a dry, cool place, and hang the asunder open ends of the hose downward to allow any wet to escape.

Source: https://ipowertoolz.com/how-to-use-campbell-hausfeld-air-compressor/